- URC Manuals
- Test Equipment
- Quick start manual
URC AC-PRO-II Quick Start Manual
- page of 16 Go / 16
Table of Contents
1 introduction and product overview, 2 commissioning the ac-pro-ii.
- Security Code
- Time and Date Setting
3 Rotating the Display
5 menu navigation, 6 external connections, 7 quick-trip system (optional).
- QUICK-TRIP Basics & Operation
- AC-PRO-II QUICK-TRIP Switch Mounting
- Remote QUICK-TRIP Switch
- QUICK-TRIP ® Remote Indication
8 USB Extension Cable
- USB Extension Cable Installation
9 Normal Operations & Readings
10 infopro-ac tm software application, 11 firmware versions and updates, appendix a - time current curves (tcc), appendix a.1: overload tcc, appendix a.2: ground fault (gf) tcc, appendix a.3: neutral overload (nol) tcc, appendix a.4: quick-trip ground fault and quick-trip instantaneous tccs.
Advertisement
Quick Links
Related manuals for urc ac-pro-ii, summary of contents for urc ac-pro-ii, page 3: table of contents, page 4: commissioning the ac-pro-ii, page 5: testing, page 6: external connections.
- Page 7 VERIFY SETTINGS AND UNIT HARDWARE IS CAPABLE OF PHASE LOSS PROTECTION. SETTINGS SAVED NOTE: THIS IS A TYPICAL MAP. SCREENS & SEQUENCES VARY DEPENDING ON ORDER CODES AND SETTINGS. Figure E: Typical AC-PRO-II Menu Navigation Map - Simple View Page 5...
Page 8: Quick-Trip System (Optional)
Page 9: ac-pro-ii quick-trip switch mounting, page 10: usb extension cable, page 11: normal operations & readings, page 12: appendix a - time current curves (tcc), page 13: appendix a.2: ground fault (gf) tcc, page 14: appendix a.3: neutral overload (nol) tcc, page 15: appendix a.4: quick-trip ground fault and quick-trip instantaneous tccs.
- Page 16 ⨀ 䤀 ⴀ 䄀 䌀 ⴀ 倀 刀 伀 ⴀ 䤀 䤀 ⴀ 儀 匀 ⨀ 䌀 栀 愀 最 爀 椀 渀 䘀 愀 氀 氀 猀 Ⰰ 伀 䠀 㐀 㐀 ㈀ ㌀ 倀 栀 漀 渀 攀 㨀 㠀 㠀 㠀 ⸀ ㈀ 㠀 㤀 ⸀ ㈀ 㠀 㘀 㐀 䤀...
Rename the bookmark
Delete bookmark, delete from my manuals, upload manual.
GE AKR-6D-30H 800A Air Breaker AC-Pro Trip Unit w/ Quick-Trip QT-Display 800 Amp (DW4344-4)
General electric ge, mpn: akr-6d-30h used low voltage power circuit breaker 800 amp frame.
For more Information please see the following link:
- description
Additional info
Description.
IMAGES
VIDEO
COMMENTS
The AC-PRO-II® is also compatible with Utility Relay Company's SAFE-T-TRIP® which provides a means for an operator to safely trip a breaker without having to stand directly in front of the switchgear. Solid-state trip unit retrofit conversion kits for General Electric, Siemens, Allis-Chalmers,Brown Boveri, Mears, English Electric, Sylvania ...
The AC-PRO ® Trip unit is a solid state, true RMS sensing overcurrent device for use on 600 volt class circuit breakers. The AC-PRO ® comes standard with Long-Time, Short-Time, Instantaneous, Ground Fault, and Phase Unbalance protections. Each of these protective features can be turned on or off at any time except for the Long-Time setting.
The AC-PRO is a state of the art, micro-controller based trip unit for use on three phase, 600 Volt class, AC circuit breakers. Models are available for use on 60 Hz, 50 Hz, 40 Hz, and 25 Hz systems. The AC-PRO is a digital trip unit that uses a micro-controller and a 16-character liquid crystal display (LCD).
The external connections are made to the top of the AC-PRO trip unit (or the left or right side for the vertical versions). Figure 4.1 AC-PROTM Top View The breaker wiring harness connects the trip unit to the CTs and actuator. The wiring harness plugs into the 10-pin connector on the top of the trip unit and is retained with two screws.
The Latest Trip Unit Features in a Smaller More Versatile Package Trip Unit Micro-controller based UTILITYRELAY.COM 888-289-2864 InfoPro-AC is a Graphical User Interface application available for easy interface between a computer and the USB port on the AC-PRO-II. InfoPro-AC will include the following features: R AC-PRO-II Settings. (Upload &
AC-PRO Direct Replacement. The AC-PRO trip unit is designed to use existing 1⁄2 or 1 amp CTs and operate the magnetically latched OEM actuators used with many older style electronic trip units. Reusing the existing CTs and actuator can greatly reduce material costs and cuts installation time to a fraction of that required for a complete retrofit.
To secondary injection test the AC-PRO trip unit with this type of test set, the AC-PRO trip unit must be isolated from This test set can test 60Hz, 50Hz, 40Hz and 25Hz the test set ground. Page 22: Lt Delay Testing Chart Utility Relay Company 12.3 LT Delay Testing Chart This chart provides trip times in Seconds for the LT Delay The Time ...
The AC -PRO is a state of the art, micro - controller based trip unit for use on three phase, 600 Volt class, AC circuit breakers. The AC -PRO is a digital trip unit t hat uses a Motorola 8 -bit micro -controller and a 16 -character liquid crystal display (LCD). The AC -PRO measures the true RMS current through each of the breaker's three poles.
AC-PRO-II® is Your Solution. AC-PRO-II ® is the solution you need to modernize and extend the life of your legacy GE circuit breakers. AC-PRO-II ® is our industry-leading low voltage trip unit providing all the features you would expect (and even some that you wouldn't!) in modern protection devices. Fine-tunable LSIG curves for precise ...
The AC-PRO is a state of the art, micro-controller based trip unit for use on three phase, 600 Volt class, AC circuit breakers. Models are available for use on 60 Hz, 50 Hz, 40 Hz, and 25 Hz systems. 3.1 Current Transformer (CT) Power The AC-PRO is a digital trip unit that uses a micro-controller and a 16-character liquid crystal display (LCD).
Page 9: Ac-Pro-Ii Quick-Trip Switch Mounting. Attach the QUICK-TRIP Switch to the front of the cubicle door using the two (2) supplied 10-32 screws and lock Figure I: AC-PRO-II Quick-Trip Switch washers. Connect the QUICK-TRIP Switch to the AC-PRO-II trip ® Remote QUICK-TRIP Switch unit by plugging one end of the 4/C cable provided into the ...
This video provides a quick rundown of the advantages of the AC-PRO-II Trip unit over it's predecessor, the AC-PRO.
the AC-PRO trip unit (or the left or right side for the vertical versions). Figure 4.1 AC-PRO Top View The breaker wiring harness connects the trip unit to the CTs and actuator. The wiring harness plugs into the 10-pin connector on the top of the trip unit and is retained with two screws. Terminal Function Color Code
Includes AC-Pro Trip Unit With Quick-Trip and QT-Display 30 day warranty on all purchases. Your purchase will include what is pictured and described above ONLY. For more info or pictures please visit our FAQs or contact us: 423 821-4712 - [email protected]. For more Information please see the following link:
How to program the Settings in the AC-PRO trip unit
AC-PRO-II® Instruction Manual rev 2.03 www.utilityrelay.com Page 3 1.0 Introduction and Product Overview The AC-PRO-II® is a state of the art, micro-controller based trip unit for use on three phase, 600 Volt class, AC circuit breakers on 50 Hertz or 60 Hertz systems. The AC-PRO-II
the AC-PRO trip unit. The test set features a selectable frequency for testing the 60Hz, 50Hz, 40Hz and 25Hz versions of the AC-PRO. AC-PRO Direct Replacement The AC-PRO trip unit is designed to use existing ½ or 1 amp CTs and operate the magnetically latched OEM actuators used with many older style electronic trip units.
The AC-PRO-ECS/SST is a True RMS trip unit designed to directly replace obsolete trip devices originally supplied on older style GETM AKR-4x and AKR-5x air circuit breakers. These trip devices include: Type-ECSTM Type-SSTTM. The AC-PRO-ECS/SST mounts directly in place of the OEM trip device and mates with the existing breaker's wiring harness.
AC-PR() "'as tested by an ifióepencient laaoratary and found in the fc\lowing tests RF Surge. 15KV Çlerarc-S,'îfic Pacc 2 Tfte AC-?RO is a o; the micro- trip unit f/ùr c;se on three phase, Volt AC circuit breakers. AC-PRO is a tria unit that micro-contraller and a Character display (LCD). Th3 AIC-PRO tft¿ RMS o: pcies.
The AC-PRO-II trip unit consists of a main case and a display case. The trip unit orientation can be modified by rotating the display case. Refer to the AC-PRO-II retrofit kit installation manuals for your breaker-specific trip unit orientation. To rotate the Display Case: • The breaker must be out of service and de-energized for safety.
3.0 Trip Unit Power ..... 5 3.1 Current Transformer (CT) Power ..... 5 3.2 Battery Power ..... 5 3.3 USB Power ..... 5 3.4 24VDC Auxiliary Power ..... 5 3.5 Voltage Divider Module (VDM) Power ..... 5 4.0 AC-PRO-II® Pictures and Configurations ... AC-PRO-II ® Instruction Manual ...
The QT-Display is a read only device that extends the use of the AC-PRO ® to a more convenient and safe location for personnel to view the continuously displayed 3-phase current, the "PICK-UP" LED, "Self-Test" LED and review last trip data and unit settings. All of this can be done without opening the cubicle door.
Utility Relay Company is a leading manufacturer of microcontroller based, true-RMS solid-state trip units and trip unit retrofit conversion kits for AC and DC power circuit breakers. The end result is an extensive line of retrofit kits that both provide reliable protection and are easy to install.